1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
|
-- C393A02.A
--
-- Grant of Unlimited Rights
--
-- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
-- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained
-- unlimited rights in the software and documentation contained herein.
-- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making
-- this public release, the Government intends to confer upon all
-- recipients unlimited rights equal to those held by the Government.
-- These rights include rights to use, duplicate, release or disclose the
-- released technical data and computer software in whole or in part, in
-- any manner and for any purpose whatsoever, and to have or permit others
-- to do so.
--
-- DISCLAIMER
--
-- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
-- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED
-- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
-- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE
-- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
-- PARTICULAR PURPOSE OF SAID MATERIAL.
--*
--
-- OBJECTIVE:
-- Check that a dispatching call to an abstract subprogram invokes
-- the correct subprogram body of a descendant type according to
-- the controlling tag.
-- Check that a subprogram can be declared with formal parameters
-- and result that are of an abstract type's associated class-wide
-- type and that such subprograms can be called. 3.4.1(4)
--
-- TEST DESCRIPTION:
-- This test declares several objects of types derived from the
-- abstract type as defined in the foundation F393A00. It then calls
-- various dispatching and class-wide subprograms using those objects.
-- The packages in F393A00 are instrumented to trace the flow of
-- execution.
-- The test checks for the correct order of execution, as expected
-- by the various calls.
--
-- TEST FILES:
-- The following files comprise this test:
--
-- F393A00.A (foundation code)
-- C393A02.A
--
--
-- CHANGE HISTORY:
-- 06 Dec 94 SAIC ACVC 2.0
-- 19 Dec 94 SAIC Removed RM references from objective text.
-- 05 APR 96 SAIC Update RM references for 2.1
--
--!
with Report;
with F393A00_0;
with F393A00_1;
with F393A00_2;
with F393A00_3;
with F393A00_4;
procedure C393A02 is
A_Windmill : F393A00_2.Windmill;
A_Pump : F393A00_3.Pump;
A_Mill : F393A00_4.Mill;
A_Windmill_2 : F393A00_2.Windmill;
A_Pump_2 : F393A00_3.Pump;
A_Mill_2 : F393A00_4.Mill;
B_Windmill : F393A00_2.Windmill;
B_Pump : F393A00_3.Pump;
B_Mill : F393A00_4.Mill;
procedure Swapem( A,B: in out F393A00_2.Windmill'Class ) is
begin
F393A00_0.TC_Touch('x');
F393A00_2.Swap( A,B );
end Swapem;
function Zephyr( A: F393A00_2.Windmill'Class )
return F393A00_2.Windmill'Class is
Item : F393A00_2.Windmill'Class := A;
begin
F393A00_0.TC_Touch('y');
if not F393A00_1.Initialized( Item ) then -- b
F393A00_2.Initialize( Item ); -- a
end if;
F393A00_2.Stop( Item ); -- f / mff
F393A00_2.Add_Spin( Item, 10 ); -- e
return Item;
end Zephyr;
function Gale( It: F393A00_2.Windmill ) return F393A00_2.Windmill'Class is
Item : F393A00_2.Windmill'Class := It;
begin
F393A00_2.Stop( Item ); -- f
F393A00_2.Add_Spin( Item, 40 ); -- e
return Item;
end Gale;
function Gale( It: F393A00_3.Pump ) return F393A00_2.Windmill'Class is
Item : F393A00_2.Windmill'Class := It;
begin
F393A00_2.Stop( Item ); -- f
F393A00_2.Add_Spin( Item, 50 ); -- e
return Item;
end Gale;
function Gale( It: F393A00_4.Mill ) return F393A00_2.Windmill'Class is
Item : F393A00_2.Windmill'Class := It;
begin
F393A00_2.Stop( Item ); -- mff
F393A00_2.Add_Spin( Item, 60 ); -- e
return Item;
end Gale;
begin -- Main test procedure.
Report.Test ("C393A02", "Check that a dispatching call to an abstract "
& "subprogram invokes the correct subprogram body. "
& "Check that a subprogram declared with formal "
& "parameters/result of an abstract type's "
& "associated class-wide can be called" );
F393A00_0.TC_Validate( "hhh", "Mill declarations" );
A_Windmill := F393A00_2.Create;
F393A00_0.TC_Validate( "d", "Create A_Windmill" );
A_Pump := F393A00_3.Create;
F393A00_0.TC_Validate( "h", "Create A_Pump" );
A_Mill := F393A00_4.Create;
F393A00_0.TC_Validate( "hl", "Create A_Mill" );
--------------
Swapem( A_Windmill, A_Windmill_2 );
F393A00_0.TC_Validate( "xc", "Windmill Swap" );
Swapem( A_Pump, A_Pump_2 );
F393A00_0.TC_Validate( "xc", "Pump Swap" );
Swapem( A_Mill, A_Mill_2 );
F393A00_0.TC_Validate( "xk", "Pump Swap" );
F393A00_2.Initialize( A_Windmill_2 );
F393A00_3.Initialize( A_Pump_2 );
F393A00_4.Initialize( A_Mill_2 );
B_Windmill := A_Windmill_2;
B_Pump := A_Pump_2;
B_Mill := A_Mill_2;
F393A00_2.Add_Spin( B_Windmill, 123 );
F393A00_3.Set_Rate( B_Pump, 12.34 );
F393A00_4.Add_Spin( B_Mill, 321 );
F393A00_0.TC_Validate( "aaaeie", "Setting Values" );
declare
It : F393A00_2.Windmill'Class := Zephyr( B_Windmill ); -- ybfe
XX : F393A00_2.Windmill'Class := Gale( B_Windmill ); -- fe
use type F393A00_2.Rotational_Measurement;
begin
if not F393A00_1.Initialized( It ) or not F393A00_1.Initialized( XX )
then
Report.Failed( "Copy to class-wide variable" );
end if; -- bb
if F393A00_2.Spin( It ) /= 10 -- g
or F393A00_2.Spin( XX ) /= 40 then -- g
Report.Failed( "Call to class-wide operation" );
end if;
F393A00_0.TC_Validate( "ybfefebbgg", "Windmill Zephyr" );
end;
declare
It : F393A00_2.Windmill'Class := Zephyr( B_Pump ); -- ybfe
XX : F393A00_2.Windmill'Class := Gale( B_Pump ); -- fe
use type F393A00_2.Rotational_Measurement;
begin
if not F393A00_1.Initialized( It ) or not F393A00_1.Initialized( XX )
then
Report.Failed( "Bad copy to class-wide variable" );
end if; -- bb
if F393A00_2.Spin( It ) /= 10 -- g
or F393A00_2.Spin( XX ) /= 50 then -- g
Report.Failed( "Call to class-wide operation" );
end if;
F393A00_0.TC_Validate( "ybfefebbgg", "Pump Zephyr" );
end;
declare
It : F393A00_2.Windmill'Class := Zephyr( B_Mill ); -- ybmffe
XX : F393A00_2.Windmill'Class := Gale( B_Mill ); -- mffe
use type F393A00_2.Rotational_Measurement;
begin
if not F393A00_1.Initialized( It ) or not F393A00_1.Initialized( XX )
then
Report.Failed( "Bad copy to class-wide variable" );
end if; -- bb
if F393A00_2.Spin( It ) /= 10 -- g
or F393A00_2.Spin( XX ) /= 60 then -- g
Report.Failed( "Call to class-wide operation" );
end if;
F393A00_0.TC_Validate( "ybmffemffebbgg", "Mill Zephyr" );
end;
Report.Result;
end C393A02;
|