summaryrefslogtreecommitdiff
path: root/gcc/testsuite/ada/acats/tests/c9/c974007.a
blob: 07007b9bb567d70bb9ffff5780921ccce2e84c4d (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
-- C974007.A
--
--                             Grant of Unlimited Rights
--
--     Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,
--     F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained 
--     unlimited rights in the software and documentation contained herein.
--     Unlimited rights are defined in DFAR 252.227-7013(a)(19).  By making 
--     this public release, the Government intends to confer upon all 
--     recipients unlimited rights  equal to those held by the Government.  
--     These rights include rights to use, duplicate, release or disclose the 
--     released technical data and computer software in whole or in part, in 
--     any manner and for any purpose whatsoever, and to have or permit others 
--     to do so.
--
--                                    DISCLAIMER
--
--     ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR
--     DISCLOSED ARE AS IS.  THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED 
--     WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE
--     SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE 
--     OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A
--     PARTICULAR PURPOSE OF SAID MATERIAL.
--*
--
-- OBJECTIVE:
--      Check that the sequence of statements of the triggering alternative
--      of an asynchronous select statement is not executed if the triggering
--      statement is a protected entry call, and the entry is not accepted
--      before the abortable part completes. Check that execution continues
--      immediately following the asynchronous select.
--
-- TEST DESCRIPTION:
--      Declare a main procedure containing an asynchronous select with a
--      protected entry call as triggering statement. Declare a protected
--      procedure which sets the protected entry's barrier true. Ensure
--      that the entry call is never accepted by not calling the protected
--      procedure; the barrier remains false, and the entry call from
--      asynchronous select is queued. Since the abortable part will complete
--      before the entry is accepted, the sequence of statements of the
--      triggering alternative is never executed.
--
--
-- CHANGE HISTORY:
--      06 Dec 94   SAIC    ACVC 2.0
--
--!


package C974007_0 is  -- Automated teller machine abstraction.


   -- Flags for testing purposes:
   -- 
   Abortable_Part_Executed       : Boolean := False;
   Perform_Transaction_Executed  : Boolean := False;
   Triggering_Statement_Executed : Boolean := False;


   type Key_Enum is (None, Cancel, Deposit, Withdraw);

   type Card_Number_Type is private;
   type Card_PIN_Type    is private;
   type ATM_Card_Type    is private;


   Transaction_Canceled : exception;


   protected type ATM_Keyboard_Protected is
      entry Cancel_Pressed;
      procedure Read_Key;
   private
      Last_Key_Pressed : Key_Enum := None;
   end ATM_Keyboard_Protected;


   procedure Read_Card (Card : in out ATM_Card_Type);

   procedure Validate_Card (Card : in ATM_Card_Type);

   procedure Perform_Transaction (Card : in ATM_Card_Type);

private

   type Card_Number_Type is range   1 .. 9999;
   type Card_PIN_Type    is range 100 ..  999;

   type ATM_Card_Type is record
      Number : Card_Number_Type;
      PIN    : Card_PIN_Type;
   end record;

end C974007_0;


     --==================================================================--


with Report;
package body C974007_0 is


   protected body ATM_Keyboard_Protected is

      -- Barrier is false for the live of the test
      entry Cancel_Pressed when (Last_Key_Pressed = Cancel) is  
      begin                                                     
      Triggering_Statement_Executed  := true;   -- Test has failed
      -- (Note: cannot call Report.Failed in the protected entry body]
      end Cancel_Pressed;

      procedure Read_Key is                                     -- Never
      begin                                                     -- called.
         -- Simulate a procedure which reads user keyboard input, and
         -- which is called by some interrupt handler.
         Last_Key_Pressed := Cancel;
      end Read_Key;

   end ATM_Keyboard_Protected;


   procedure Read_Card (Card : in out ATM_Card_Type) is
   begin
      Card.Number := 9999;
      Card.PIN    := 111;
   end Read_Card;


   procedure Validate_Card (Card : in ATM_Card_Type) is
   begin
      Abortable_Part_Executed := True;
   end Validate_Card;


   procedure Perform_Transaction (Card : in ATM_Card_Type) is
   begin
      Perform_Transaction_Executed := True;
   end Perform_Transaction;


end C974007_0;


     --==================================================================--
with Report;

with C974007_0;  -- Automated teller machine abstraction.
use  C974007_0;

procedure C974007 is

   Card_Data : ATM_Card_Type;

begin

   Report.Test ("C974007", "ATC: trigger is protected entry call" &
                              " and abortable part completes first");

   Read_Card (Card_Data);

   declare
      Keyboard : C974007_0.ATM_Keyboard_Protected;
   begin

      --                                    --
      -- Asynchronous select is tested here --
      --                                    --

      select
         Keyboard.Cancel_Pressed;        -- Barrier is never set true, so
                                         -- entry call is queued and never
                                         -- accepted.

         raise Transaction_Canceled;     -- Should not be executed.
      then abort
         Validate_Card (Card_Data);      -- This call completes before
                                         -- Keyboard.Cancel_Pressed can be
                                         -- accepted.
      end select;
      Perform_Transaction (Card_Data);   -- Execution proceeds here after
                                         -- Validate_Card completes.
   exception
      when Transaction_Canceled =>
         Report.Failed ("Triggering alternative sequence of statements " &
                        "executed");
   end;
   
   
   if Triggering_Statement_Executed  then
      Report.Failed ("Triggering statement was executed");
   end if;

   if not Abortable_Part_Executed then
      Report.Failed ("Abortable part not executed");
   end if;

   if not Perform_Transaction_Executed then
      Report.Failed ("Statements following asynchronous select not " &
                     "executed");
   end if;

   Report.Result;

end C974007;